This term refers to all circuit conductors between service equipment and the final branch circuit overcurrent device.
What is a Feeder
These overhead conductors are installed, owned, and maintained by the utility, not the electrician .
What is the service drop
This NEC section requires protection of underground service entrance conductors against physical damage.
What is NEC 230.50
This NEC section requires an emergency disconnect in a readily accessible outdoor location for one and two family dwellings
What is NEC 230.85
what is 77+33
110
This NEC article contains the definition of "service" and "service point".
What is NEC Article 100
This minimum clearance is required above a residential driveway for service conductors under 300 volts to the ground.
This minimum burial depth is required for most residential underground service laterals
What is 24 Inches
This marking must appear on a service disconnect used as the emergency disconnect.
What is Emergency Disconnect/Service Disconnect.
This is the point where the utility's wiring ends and the customers wiring begins.
What is the Service Point
This type of service uses conductors or cable installed underground from the utility system to the service equipment.
What is an Underground Service
This Warning material must be installed above underground wiring per NEC 300.5 (D) (3).
What is Buried electric warning ribbon
This is the type of surge protective device is installed on the line side of the service disconnect
What is a Type 1 SPD
Name All 7 Continents
This minimum ampacity is required for a one family dwelling service disconnect according to NEC 230.79 (C).
What is 100 amperes
Only these types of conductors are allowed to be attached to a service mast according to NEC 230.28.
What are Power service drop or overhead service conductors.
These conductors typically run from a pad mounted transformer to the meter location in an underground service.
What are service lateral conductors.
This NEC section requires every circuit and circuit modification to have a clear, permanent description
what is NEC 408.4
who won in Shawn v Lekki
Shawn
These conductors run from the service equipment to the first overcurrent device of a branch circuit.
This fitting is used where a service raceway passes through a roof to prevent water intrusion.
What is a Neoprene seal with metal flashing
This NEC table is used to determine burial depth for underground wiring
What is NEC Table 300.5
This minimum nominal discharge current rating is required for SPDs installed at services
What is 10 kA