Radiation Quantities & Units
Formulas
Organizations
NCRP Dose Limit Recommendations
Radiation Monitors
100

This is the first unit used to measure radiation exposure

What is Skin Erythema Dose?

100

= irradiated surface x Air Kerma

What is DAP?

100

International authority on safe use of radiation, provides guidance through recommendations for occupational and public dose limits

What is ICRP?

100

Annual EfD limit for education and training exposures

What is 1 mSv?

100

Contains Aluminum Oxide detector and uses 3 different filters

What is the Optically Stimulated Luminescent Dosimeter (OSL)?

200

Dose to which occupationally exposed persons could be continuously subjected without any apparent harmful acute effects

What is the Tolerance Dose/Threshold Dose?

200

= D x WR

What is Equivalent Dose (EqD)?

200

US nongovernmental agency. Reviews recommendations of ICRP and determines how they are incorporated into US radiation protection criteria

What is NCRP?

200

Annual EfD limit for occupational exposure

What is 50 mSv?

200

Measures x-radiation, gamma, and beta radiation. Used for calibration of X-ray and fluoro units. Also called "Cutie Pie"

What is the Ionization Chamber Survey Meter?

300

Largest dose that an occupationally exposed person was allowed that was not anticipated to result in major adverse biologic effects

What is the Maximum Permissible Dose?

300

= D x WR x WT

What is Effective Dose (EfD)?

300

Federal agency that has the power to enforce radiation protection standards. Oversee the nuclear energy industry

What is the NRC?

300

Annual non-occupational EfD limit for continuous or frequent exposure

What is 1 mSv?

300

For area monitoring & contamination control. Audible sound system to alert of presence of radiation

What is the Geiger-Muller (G-M) Detector?

400

This quantity is the BEST measure of the overall risk of radiation of various biologic tissues and organs simultaneously irradiated. Expressed in Sv

What is Effective Dose?

400

= age (in years) x 10 mSv

What is Cumulative Occupational Dose?

400

Regulates the design and manufacturing of electronic products, including diagnostic x-ray equipment. Conducts onsite inspections of x-ray equipment

What is the FDA?

400

Annual EqD limit for occupational exposure to the lens of the eye

What is 150 mSv?

400

Type of monitor worn underneath a lead apron during fluoro, mobile radiography, or surgery

What is a fetal monitor?

500

Radiation quantity that expresses how energy is transferred from a beam of radiation to air. 

What is Air Kerma?

500

= sum of all doses x number of individuals exposed

What is the Collective Effective Dose (ColEfD)?

500

Law that is strictly an equipment performance standard. The FDA uses this law to conduct inspections

What is the Public Law 90-602?

500

Monthly EqD limit for embryo and fetus exposure

What is 0.5 mSv?

500

Dosimeter that has a small piece of x-ray film sandwiched between metal filters inside a plastic holder

What is a film badge?

600

Defined as “received quantity of radiation that causes diffuse redness over skin after irradiation.”

What is Skin Erythema Dose?

600

determined by dividing the Rad value by 100

What is converting Rad to Gy?

600

International organization that evaluates human and environmental radiation exposures from a variety of sources

What is UNSCEAR?

600

Annual non-occupational EfD limit for infrequent exposure

What is 5 mSv?

600

Worn as second monitor when performing radiographic procedures that require hands to be near the primary x-ray beam

What is an extremity dosimeter (TLD ring badge)?

700

The sum total of air kerma over the exposed area of the patient's surface

What is Dose Area Product (DAP)?

700

Convert 0.020 Gy to mGy

What is 20 mGy?

700

Facilitates development and enforcement of regulations pertaining to control of radiation in the environment.

What is the EPA?

700

Entire gestation EqD limit for the embryo and fetus exposure

What is 5.0 mSv?

700

Contains Lithium Fluoride crystals and can measure exposures as low as 5 mR

What is the Thermoluminescence Dosimeter (TLD)?

800

The amount of energy per unit mass absorbed by the irradiated object. Depends on the energy of the beam, atomic number and the mass density of the tissue

What is Absorbed Dose (D)?

800

Determined by multiplying the Gy value by 100

What is converting Gy to Rad?

800

Regulates occupational exposure through: Part 1910 of Title 29 of the US Code of Federal Regulations (29 CFR 1910)

What is OSHA?

800

Annual EfD limit for localized areas of the skin, hands, and feet for education and training exposures

What is 50 mSv?

800

contains an ionization chamber

What is a Pocket Dosimeter?

900

Quality factor for fast neutrons, low-energy internal protons, alpha particles, and multiple charged particles of unknown energy

What is 20?

900

If 300 people receive an average EfD of 0.30 Sv, what is the ColEfD in person-sievert?

What is 90 person-Sv?

900

Provides federal legislation to establish minimal standards for accreditation of education programs for those who administer radiologic procedures and their certification

What is the Consumer-Patient Radiation Health & Safety Act of 1981?

900

Annual non-occupational EfD limit for the lens of the eye 

What is 15 mSv?

900

Serves as a basis for comparison with other badges and kept in a radiation free area

What is the control monitor?

1000

Quality factor for X-ray photons, beta particles, gamma photons, and high-energy external protons

What is 1?

1000

The WR for alpha particles is 20, and the WT for the breast is 0.05. If the breast receives a D of 0.5 Gy from exposure to alpha particles, what is the EfD in Sv?

What is 0.5 Sv?

1000

Scholarly committee that reviews studies of biologic effects of ionizing radiation and risk assessment

What is NAS/NRC-BEIR?

1000

Annual negligible individual EfD limit

What is 0.01 mSv?

1000

Resembles a flash drive and contains a small ionization chamber and provides an instant read-out of dose information when connected to a computer

What is a direct ion storage dosimeter (DIS)?

M