WHAT IS THE TIRE AND WHEEL PUBLICATION.
NA 17-1-129
WHEN WORKING ON ELECTRICAL EQUIPMENT WHAT ITEMS NEED TO BE REMOVED FROM YOUR PERSON BEFORE YOU START WORK?
ALL METAL AND CONDUCTIVE ITEMS IE: WATCHES, BELTS, METAL RINGS, ETC.
WHAT IS 4790/64
Support Equipment Transaction Report
WHAT IS THE CORROSION PUBLICATION?
17-1-125.
WHAT IS ACTION TAKEN CODE "Z"?
WHAT SHOULD A TIRE BE INFLATED TO FOR STORAGE PURPOSE?
50% OF SERVICE PRESSURE OR 15 PSI (WHICHEVER IS LOWER).
WHAT IS THE RATED CAPACITY OF THE A/M24M-6 AC SIDE.
120 KVA, 115/200 volts, 3 phase, 400 Hz
WHAT ARE THE PRINCIPLES OF THE TOOL CONTROL PROGRAM?
Standardization of tools and the configuration of tool containers.
Traceability of tools through the use of unique identification numbers.
Strict accounting of tools.
WHAT IS A TPDR?
Technical Publication Discrepancy Report
WHAT IS WORK UNIT CODE (WUC) 090 USED FOR?
NON AVIATION EQUIPMENT
WHAT IS THE PUBLICATION FOR THE TIRE INFLATOR KITS AND WHAT DO YOU VERIFY BEFORE YOU USE THE INFLATOR KIT?
NA 17-1-123, VERIFY CALIBRATION AND THE WHITE O-RING ON THE FITTING.
WHAT ARE THE POWER INPUT REQUIREMENTS FOR THE A/M24M-5A? HOW MANY OUTPUTS AND WHAT ARE THEY?
INPUT (440/220 VAC, 3-phase, 60/50 Hz)
3 OUTPUTS
115 VAC (115 VAC, 3-phase, 400 Hz)
28 VDC (28VDC 14KW Continuous)
270 VDC (270VDC 72 KW CONTINUOUS)
WHAT ARE THE 4 DIFFERENT TYPES OF AUDITS?
PROGRAMS, QA, WORKCENTER, SPECIAL
WHAT IS THE LAST 2 DIGITS ON A PUBLICATION FOR AN MRC CARD ON SE?
6-2
WHAT IS MAL CODE "105"
LOOSE, MISSING, FAULTY
HOW DO YOU FIND THE TORQUE SPEC OF A NUT IAW NA 17-1-129?
VERIFY THE THREAD SIZE TO THE WRENCH
WHAT IS THE DIFFERENCE BETWEEN A WIRING DIAGRAM AND A WIRING SCHEMATIC?
DIAGRAM SHOWS THE INDIVIDUAL COMPONENTS
SCHEMATIC SHOWS YOU WHERE THAT INDIVIDUAL WIRE LEADS TO.
Conventional Ordnance Discrepancy Reports, 24 HOURS
WHAT WP OF THE 17-1-125 COVERS PRESERVATION AND DEPRESERVATION?
WORK PACKAGE 11
WHAT IS THE ONE JOB STATUS CODE THAT DOES NOT SHOW UP ON THE BMT AND WHAT DOES IT MEAN?
M9
AWAITING FUNDING
HOW LONG DOES A TIRE STAY IN THE INFLATOR CAGE DURING PRESSURE TEST?
10 MINUTES.
WHAT DOES A TRANSFORMER RECTIFIER DO ON A A/M24M-6?
CONVERTS THE AC POWER PRODUCED FROM THE GENERATOR INTO DC POWER.
CAT 1 PQDR will be submitted for quality deficiencies with the potential to cause death, injury, or severe occupational illness; or result in a production line stoppage at original equipment manufacturer (OEM).
Y CODE is a supply turn in issued from an I-level installation.
WHAT WORK PACKAGE IN THE PUBLICATION COVERS TROUBLESHOOTING STEPS?
WORK PACKAGE 6
WHAT IS TRANS CODE WHEN COMPLETING A TD(TECHNICAL DIRECTIVE)?
41