NEC CODE ARTICLES
Electrical Measurements
Devices
Grounding & Bonding
Electrical Field Slangs
100

This article covers general requirements for grounding and bonding of electrical installations

What is article 250-grounding and bonding

100

This is the maximum height required by NEC to for a  breaker to be at

What is 6' 7"

100

This device is used everyday in every household

What is TR outlet

100

I am required to be attached to any metal box

What is a ground screw

100

This word means -Pre-drywall wiring stage 

 What is Rough-in

200

This device intended for the protection of personnel that functions to de energize a circuit when a ground fault is detected.

What is 210.8-GFCI Protection

200

This is the minimum clearance of working space in front of an electrical panel

What is 3'

200

When i walk in a room this device turns on my light hands free.

What is a motion switch

200

This wire is attached from the metal box to a device. 

What is the equipment bonding jumper.

200

This word means-Devices, lights, plates stage 

What is Trim-out

300

This article covers conductor ampacity of wire

What is table 310.16

300

This  measurement of a required receptacle must be within ____ after a doorway

What is 6'

300

This device helps prevent injury when a vacuum is faulty and is plugged in

What is an arch fault breaker

300

What is the minimum requirement for ground rod spacing

What is 6'

300

This is a slang word for wirenuts

What is Beans

400

This article covers the installation of wiring and equipment in the areas fixed or floating piers, docks, marinas, boat yards & floating buildings

What is article 555.1-Marians,boat yards, floating buildings

400

if a counter space is ____ or more a counter outlet is required.

What is 12"

400

I mostly have no power but when i do have power, I'm glad i am on.

What is a portable generator outlet.

400

This material has female threads and shall be provided to ensure electrical continuity and the capacity to conduct safely and likely fault

What is a bonding bushing

400

This is a slang word for Induced voltage reading 

What is ghost voltage

500

This article applies to the installation and operation of optional standby systems

What is article 702-Optional Standby Systems

500

When in stalling 2" PVC, this is the required spacing in between support when running PVC horizontal.

What is every 5'-

Table 352.30(B)

500

I come in many different styles and brands, but i am the most important when i am in the on position. 

What is a main breaker

500

The connection between the grounded circuit conductor and the equipment grounding conductor or the supply -side bonding jumper, or both at the service

What is the bonding jumper(main bonding jumper)

500

This is a slang word for Nuisance breaker trip 

What is Phantom trip 