Sink or Swim
Name That Energy Recovery Device
Controls but with a Clever Title
So you think you're cool?
Other stuff that may or may not have fit into another category
100

In typical pool operation, the percentage of OA ranges from this to this.

What is 25-50%

100

This is the energy recovery device that Innovent makes in their factory.

What is a sensible flat plate heat exchanger?

100

This is the standard Innovent controller brand.

What is Carel?

100

These are two ways (of many) to decrease the sound of a custom DX system.

Low Sound Condenser fans

Housed compressor sections

Compressor sound blankets

100

This is a fantastic way to engage customers and get them familiar with Innovent as a brand and a company.

What is a customer visit?

200

These are two reasons Innovent pools are a sweet spot

What are Better IAQ due to more OA, Lower Operating cost, Simpler to Control, Easier to install, Factory Support During design, Repeatable, Energy Calculation Ability, Experience implementing this design

200

This energy recovery device consists of aluminum plates interwoven with a polymer membrane

What is an enthalpic plate heat exchanger

200

This allows users to view their Innovent unit operation through the internet if they connect and ethernet cable to the unit.

What is WebUI?

200

These are two ways (of many) Innovent has flexibility in designing refrigeration systems.

Non-standard aspect ratios of coils and refrigeration components

Variable rows, circuiting, dimensions on evap and condensing coils

Condenser fan and compressor options

Control sequence adaptability

Sound control through fans, sound blankets, housed compressors...

200

This is Innovent's closure rate on Basis of Design Pools.

What is 90%

300

This is the first stage of dehumidification in an Innovent Pool Unit

What is Outside Air

300

This energy recovery system features two energy recovery devices and wraps around the second energy recovery device with the goal of providing room neutral air.

What is a LASER-2

300

This is where you can go to find the Innovent Controls IOM.

What is Repnet?

300

On average, this is how many Innovent jobs ship with refrigeration

What is 50%

300

This is Innovent's new design program that you have access to right now. 

What is Specmate?

400

This is when the compressors run in an Innovent Pool unit.

What is the outside air damper at maximum and space humidity above setpoint.

400

This energy recovery device does sensible only energy recovery but has the advantage of being able to have air tunnels in different units and different locations.

What is a run around glycol loop?

400

This is the sensor we use to put flat plate heat exchangers in defrost mode.

What is an Exhaust Leaving Air Temperature Sensor

400

This is the lowest discharge air temp that Innovent can achieve off of a custom DX system.

What is 42.

400

If Steve Grandelis was going to pick three things that Innovent was good at, this is what he would say.

High amounts of outside air, custom refrigeration, and controls

500

These are two of the things that ASHRAE 62.1 doesn't take into account for pool ventilation

Space height

Air Distribution

Activity of the space

500

This energy recovery device features dampers that control the flow of air through a media

What is Accubloc?

500

These are two reasons why Controls are a sweet Spot for Innovent.

Experience in custom refrigeration control

Standard selectable, tested sequences

On staff controls engineers

Factory mounted controls

500

These are two reasons (of many) why you would use a custom DX system for your application.

non-standard fan, coil and compressor types required

Design efficiency strategy

Dimensional constrains for refrigeration system

Limited Space available/job constraints 

limited location for outdoor air and exhaust louvers

Custom control sequence required

Aesthetically pleasing/curbside appeal

ability to locate in different locations/orientations

Sound

"plug and play" packaged unit is easier to install and less risk

Differentiation from competition

Large custom unit or high rise replacements

Full redundancy

500

This is the best way to get an Innovent job.

BOD

M