RV's and RV Parks
Marinas & Docks & Stuff
Temporary Installations
Definitions
Surprise
100

True or False: non-metallic boxes shall be acceptable only with metallic-sheathed cable and metallic raceways.

What is...True - 551.47 (c)

100

This code covers ground fault protection of floating buildings...

What is...555.63

100

NEC 590.3 States...

What is... REMOVAL- Temporary wiring shall be removed immediately upon completion of construction or purpose for which the hiring was installed.

100

Fixed Appliance

What is... an appliance that is fastened or otherwise secured at a specific location.
100

Article 590! First definition!...GO!

What is...Despite the excitement...There are no listed definitions in article 590.
200

The working clearance for an RV Panelboard

What is...24 in. wide 30 in. deep - 551.45 (b)

200

The code cord-connected appliances for floating buildings is...

What is... 555.56 (b)

200

This code covers "protection from accidental damage"...

What is...590.4 (h)

200

Recreational Vehicle Site

What is...  A specific area within a recreational vehicle park or camp ground that is set aside for use by a camping unit.
200

The title of the chapter all of our assigned Jeopardy codes reside in...

What is...Special Occupancies.
300

The RV cord exposed usable length shall be measured from...

What is... The Point of entrance to the RV or face of flanged surface inlet (motor-base attachment plug) - 551.46 (b)

300

This code specifies the location of service equipment for docks and marinas... Where shall it be?

What is...It shall be on land adjacent to the structure - 555.4

300

This code covers over-current protective devices "where re-used"...

What is..590.8 (a)

300
Electrical Datum Plane
What is... A specified distance above a water level above which electrical equipment can be installed.
300

Table 551.73 (a)...WTF is that??

What is...Demand factors for site feeders and service entrance conductors for park sites.

400

This article covers combination electrical systems, generator installations and 120v, 208v/120v, or 120v/240v nominal systems.

What is...551.4 (b)

400

This code covers transformers for marine hoists, railways, cranes, and monorails. Where shall it NOT be located??

What is...It shall NOT be located below the electrical plane. - 555.8

400

This code states that temporary power shall not exceed 90 days for holiday decorative lighting and similar purposes...

What is... 590.3 (b)

400

The first definition listed under article 590...

What is... there are no listed definitions in article 590.

400
The NEC is NOT intended to be used as...
What is... a design specification or instruction manual for untrained persons.
500

This code covers "protection against physical damage" for underground services in an RV park...

What is... 551.80 (b)

500

This code specifies that the electrical connections shall be located at least 12 in. above the deck of a fixed pier, but shall NOT be located below the electrical datum plane.

What is... 555.30 (b)

500

This code covers "temporary receptacles in wet locations"...

What is...590.4 (d-2)

500

Dry Stack Storage

What is... A facility either covered or uncovered, constructed of horizontal and vertical structural members, designed to allow placement of small boats in defined spots arranged both horizontally and vertically.

500

The purpose of the NEC...

What is... Practical safeguarding of persons and property from hazards arising from the use of electricity.