Electrical
Electrical Parts
Refrigeration
AC parts
Churp
100

I am checking low voltage communication from thermostat to control board. I check from R terminal to Y terminal on the control board. I read 0 Volts AC. What have I proved to myself?

Call for outdoor unit

100

This part stores voltage then disperses it. It is a form of Resistance.

Capacitor

100

normal to low- head 

normal to High- subcool

Low- Suction

High- superheat

Liquid line restriction 

100

Used to switch unit from heating to cooling 

4 way Reversing valve 
100

What animal did the CIA surgically implant listening equipment and released them around sensitive Soviet locations during the Cold War?

Cats

200

I make a call for cooling. The blower fan runs but the outdoor unit has not come on. I check Y terminal to C terminal and read 24 volts AC on the defrost board. Then check common to Y wire on contactor and read 0 volts AC. What should I check next?

Safety switches.... Low pressure switch, High pressure switch, compressor overload.

200

This is a Relay and is like a bridge for the voltage to go across.

Contactor 

200

Low- head

Low- subcool

Low- Suction

High- superheat

has a fixed orifice piston

Low charge on system 

200

turns vapor refrigerant to liquid refrigerant.

Condenser 

200

Who was offered the Israelian presidency in 1952?

Albert Einstein

300

I noticed a humming noise from the outdoor unit. The contactor is closed and voltage is present on both high voltage and low voltage. What part should I check first? 

The Capacitor 

300

An thing that makes electricity useful.

The Load

300

Head and Suction pressures equal

System not running 

300

name the four lines of the ac cycle

discharge, liquid, expansion, suction

300

What animal is Illegal in Hawaii?

Hamsters

400

must answer both questions 

The Capacitor is a dual capacitor that must be  

50µf + 7.5µf ± 10 %    You read 46µf + 6.8µf

Is this capacitor in tolerance or not? and what is my range for both? 

45µf - 55µf + 6.75µf - 8.25µf

 and 

Yes it is in tolerance

400

Controls the system, Is considered the brain of the system.

The Control Board 
400

high- head

high- subcool

high- suction

low- superheat

fixed orifice piston

Over charged system

400

name the five type of compressors 


Screw, Scroll, Reciprocating, Rotary, Centrifugal 

400

When Babe Ruth retired, what was the MLB's career home run record?

714

500

List what Terminal controls what part of system

Y Terminal 

W Terminal

G Terminal

Y Terminal is for outdoor condenser unit

W Terminal is for Heat (gas or electric)

G Terminal is for the blower motor (indoor fan)

500

Usually closed and is wired in series with important parts. This is a category not a specific part. 

Safety Switches

500

normal-head 

normal- subcool

low- suction

high- superheat


lack of air and or not enough heat transfer

500

What does a TXV do?

maintain superheat

500

Who received a patent for a gas-powered central heating system that used ducts to deliver heat throughout a home, significantly advancing residential comfort?

Alice H. Parker in 1919