This D&S is used as a catch-all for Review of O&M Program Examinations other than High and Significant Hazard Dams.
What is FAC 01-04, Review of Operation and Maintenance (RO&M) Program Examination of Associated Facilities (Facilities Other Than High- and Significant-Hazard Dams)?
This examination is used as a general assessment of the condition of pertinent features of a dam using a checklist developed specifically for that dam. 3 words
What is an Annual Site Inspection (ASI)?
This recommendation category involves the correction of severe deficiencies where immediate and responsive action is required to ensure structural safety, operational integrity of a facility, or operating personnel/public safety.
What is Category 1?
These offices are responsible for entering O&M recommendations into the Dam Safety Information System (DSIS) and tracking their status.
Who are the regional, area, and/or field office?
Under the Reclamation Transparency Act, O&M recommendations with an estimated total cost of over $100,000 are reported through this process to identify Reclamation-wide repair needs.
What is the Major Rehabilitation and Replacement (MR&R) activities list?
Patch the cracks and seepage locations along the outlet works conduit and reexamine the conduit every 3 years or whenever the reservoir rises above 2765 feet, for development of new seeps.
SMART: Identify the shortcoming in the Rec
Specific, Measurable, Attainable, Relevant,Timely
What is Attainable
As worded, this recommendation can never be completed.
Directives and Standards provide the level of detail necessary to ensure consistent application of Policy Reclamation-wide and can be found here.
What is Reclamation Manual?
These exams are performed every 8 years, alternating every 4 with Comprehensive Reviews (CR's) and conducted by the regional office.
What are Periodic Facility Reviews (PFR's)?
Recommendations covering less important matters but believed to be sound and beneficial suggestions to improve or enhance the O&M of the project or facility. If the recommendation is still applicable, the current year designation will be reassigned to this recommendation number.
What is Category 3?
Status updates on these recommendations will be provided by the responsible area manager and regional director within DSIS on an annual basis.
What is a Category 2 O&M recommendation?
Quarterly reports on the status of incomplete O&M recommendations are provided to the regional directors. The reports identify recommendations that are considered "planned". These two fields are required in DSIS to signify a recommendation is planned.
What are CUR_SCHED_COMP_DATE and EST_COMP_COST?
Repair and anchor the buoy line upstream from the overflow spillway crest.
SMART: Identify the shortcoming in the Rec
Specific, Measurable, Attainable, Relevant,Timely
What is Timely
Because completion of this activity is critical to public safety, recommendation statement should provide completion timeframe (e.g., before threat of spill).
This Directive and Standard covers the requirements for BOTH the Review of O&M Program for High and Significant Hazard Dams and the Safety Evaluation of Existing Dams (SEED) Program.
What is FAC 01-07, Review/Examination Program for High and Significant Hazard Dams?
Periodic recreation site examinations are performed by these Reclamation groups.
Recreation program managers, area and regional facility operations and maintenance staff
At Minidoka Dam modifications were made to address ice loading on the radial gates. This type of recommendation was made to initiate modification of the facility to address a state of the art issue with the design.
What is a Safety of Dams (SOD) recommendation?
This format is used for a facility O&M Recommendation ID.
What is YYYY-Category-Letter?
(Example: 2012-2-A)
A category 2 recommendation is made for an asset that has reached the end of it's usable life and needs to be decommissioned. These offices needs to be involved in the decommissioning to complete this recommendation. (3)
Who is facility operations and maintenance, real property office, and lands and realty?
Determine type of coating applied to penstock and jet-flow gates. Research repair options.
SMART: Identify the shortcoming in the Rec
Specific, Measurable, Attainable, Relevant,Timely
What is Measurable
Completion of recommended activities may be difficult to measure. Also, these activities should be done to inform a recommendation to clean and recoat the subject metalwork.
This responsible party is involved with implementing Directives and Standards.
Who is everyone?
In this year the Review of Operation and Maintenance (RO&M) Program was established to conduct periodic examination reviews and a field examination program to identify issues at an early stage to lengthen service lives of structures and lessen expenditures.
What is 1948?
Replacing a critical cable to gate connection on a sluiceway at a Dam is this Category of Recommendation.
What is a Category 1 or a Category 2 O&M recommendation? The category will depend on the asset or component.
Group decides. Trick question? "critical" = cat 1? need more data? e.g. is there overtopping protection?
As of 2018, tracking of these types of O&M recommendations is a new requirement for High and Significant Hazard Dams.
What are all Category 3 O&M recommendations?
FAC 01-12 used to say "Cat 2", now says Recommendations.
Reclamation-wide there are this number of Category 1 O&M recommendations, which currently exist.
What is 5?
2012-South Coast Conduit System
2017-Langell Valley Irrigation District System
2018-Sumner
2019-Norman
2019-11WC0250 - West Canal, Lateral, W39.9 Bridge
Repair the air vacuum/air release valve for the 42-inch-diameter steel outlet works pipe No. 2.
SMART: Identify the shortcoming in the Rec
Specific, Measurable, Attainable, Relevant,Timely
What is Specific
Does 'repair' refer to protective coatings? Is the valve not seating properly? Something else?
Requirements for Standing Operating Procedures (SOPs), dam operating training, operating logbooks, gate exercising and testing, and related safety and security procedures are contained in this Directive and Standard.
What is FAC TRMR-66, Operating Practices and Procedures for High- and Significant-Hazard Dams (and other facilities, as applicable)?
This is the required frequency of Electromagnetic Inspections as a form of inaccessible feature examinations of Prestressed Concrete Cylinder Pipe (PCCP).
What is not required.
AFR examinations are required every 6 years under FAC 01-04; there is currently NO requirement for EM inspections of PCCP, but its GOOD idea on an approx. 6 year basis
In 2017, the Oroville Spillway failure resulted in significant economic damage and over $1 billion in repair costs. This recommendation type would be used to identify the potential for a spillway failure similar to the Oroville incident.
What is both Operation and Maintenance (O&M) and Safety of Dams (SOD) recommendations? Both are used to identify risk and reliability of facilities. A SOD recommendation may identify modifications related to a potential failure mode. Repeat O&M repairs and recommendations may identify systemic underlying facility issues which.
In addition to cultural factors, improper construction and non state of the art design may have been contributing factors
Status updates on these recommendations will be provided by the responsible area manager/regional director within DSIS and to the Director (Policy) and the Director (Operations), every 6 months (January 1 and July 1) until completed.
What is Category 1 O&M Recommendation?
Reclamation tracks incomplete O&M recommendations at all facilities. The oldest recommendation that is currently incomplete was made in this year.
What is 1986?
Upper Colorado MIDDLE RIO GRANDE CONSERVANCY DISTRICT SYSTEM: Albuquerque Division - Perform an engineering study of the feasibility of automating the Angostura Diversion Dam bypass sluice gates.
Excavate rocks and soil away from the top of the left and right outlet works stilling basin walls.
SMART: Identify the shortcoming in the Rec
Specific, Measurable, Attainable, Relevant,Timely
What is Relevant
Intent behind this recommendation is not clear but is to provide the OSHA-required 42-inch height to prevent falls. This recommendation statement unnecessarily tells operating entity how to comply with the OSHA requirement.