In which chapter would you find the article “Outside Branch-Circuits and Feeders” ?
Extra Points-
What article is “Outside Branch-Circuits and Feeders”?
What is Chapter 2?
Extra-
What is Article 215?
Intermittent operation of electrical equipment in which the load conditions are regularly recurrent is called?
What is Duty, Periodic?
Article 100
A building or structure supplied by a feeder shall have _____ installed
a grounding electrode system
250.32(A)
The ampacity of of UF cable shall be that of ___ conductors in accordance with 310.14.
What is 60 degrees?
340.80
When does a branch circuit extension NOT require AFCI protection?
if less than 6ft AND no devices are added.
210.12(D) Exception
The conductors from the service point to the service disconnecting means.
What is Service Conductors?
Article 100
The grounding ring shall be installed not less than ____ below the surface of the earth?
What is 30in.
250.53(F)
_____ is the maximum approved electrical trade size for PVC conduit.
What is 6in?
352.20(B)
A receptacle must be located within ____ft of an air conditioner
25
210.63
A device, or group of devices, or other means by which the conductors of a circuit can be disconnected from their source of supply.
What is Disconnecting Means?
Article 100
What minimum size copper bond wire is needed for equipotential bonding of pool equipment?
#8 solid
680.26(B)
What is the max distance for supports on a 3" PVC pipe?
What is 6 ft
Table 352.30
The minimum size copper ground for a 100 Amp circuit
8AWG
Table 250.122
An enclosure that is designed for either surface mounting or flush mounting and is provided with a frame, mat, or trim in which a swinging door or doors are or can be hung
Cabinet
Article 100
Equipment Grounding Conductors can be taped green at the time of installation at every accessible point, IF ____AWG or larger
4
250.119(A)
The maximum approval electrical trade size of IMC is ________?
What is 4 inch?
342.20(B)
According to the NEC®, which MINIMUM enclosure type letter would be required where the _____
installation is a motor controller located outdoors, in an area that is subject to heavy rain and snow?
Type 3
Table 110.28
The largest amount of current capable of being delivered at a point on the system during short circuit condition.
What is Fault Current, Available?
Article 100
A concrete encased electrode shall be a bare copper conductor not smaller than____?
What is #4
250.52(3)(2)
True or False
Is ENT approved for direct burial?
False.
362.12 (4)