with the auto A closed and the auto E closed the DMV is in this status
Out of service
leaving anion resin behind in the CRV can result in this condition.
none. sulfate form anion resin does not affect steam generator chemistry unless influent pH is very high.
with a conductivity of 392 uS/cm low conductivity waste will be diverted to
the raw water basin
a high level in the SGB flash tank results in this condition
A high level dump to the condenser.
when operating a component, ensuring the correct system response is the
"R" in STAR
During power ascension @ 50% power and with a polisher D/P of 59 PSID you must________
place another DMV in service
the CRV and M&H vessels both have a ____ ____
false floor
The waste recovery system is powered by this group bus.
"H" bus
the maximum level in the DM water storage tanks is
90%
Don's favorite band from the 90's who lost their lead singer to a drug overdose was
Alice in Chains
2 circulators have tripped due to grassing and condensate temperatures have increased to 138 deg F. this action must be taken in regards to the condensate polisher.
none
Failure to ensure Lh flow through the Th during rinses could result in this condition.
create a salt shaker if performing a full regen.
having a build up of iron on the WRS quartz filter can help mitigate
high TRC at the NRW basin
This method of operation used when transferring resin from a SGBD demin mixed bed to a dumpster
manual operation of the system
the scariest thing in the plant according to Don is
a steam leak
the CN108s will automatically open when this condition occurs.
none. there is no automatic function of the CN108 valves
when performing manual operations of a regen, the system will not provide this function
trip
All WRS valve switches must be in this position for the system to operate in automatic
Auto
the Demineralized Water Storge Tanks (DWST) can hold this amount of water each
500,000 gallons
____________ is the G.O.A.T band of Heavy metal
Black Sabbath
With DMV flow rates at 3000 GPM an operator should take this action
take a DMV to stand-by to increase flow rates across the remaining DMVs and prevent channeling.
with a low level in the low pit alarm locked in the regen system will
not trip
this valve is used to throttle flow through the WRS (if desired)..
2CP181
with the 2GB217 closed blowdown flow is directed to
the SGBD system and then to 23 condenser
A good operator uses these when operating plant equipment
4 of their 5 senses. sight, hearing, smell, and touch. not taste unless you want to..... i wouldn't