100

Number of calls and emails are needed before closing as unresponsive. 

3

every call should have a follow-up email- after 2 calls and emails, the adjuster should be notified the ctr is unresponsive and a deadline email sent to the contractor on the third day of no response and closed on the 4th day.

100

Tandem Axle Dump Trailer can hold this much debris

1.67 tons- similar to a 4-5yard dumpster

100

You can print a scope without opening the entire scope in Xactimate- True or False

True- If you don't know how I can teach you. 

100

Fuel Surcharge isn't standard- why?

Fuel cost is incorporated into the line items. 

This was intended as a temporary solution during COVID as the fuel cost were rising at an unprecedented rate. 

100

Required PPD for Category 2, Class 2 

CF= 13,734.88

274.69PPD 


200

Who do we request photos from

Contractor and Adjuster-if we need photos we need to also let the adjuster know so that they have a chance to send them or direct the ctr to send. 

200

Single axle dump truck holds this much debris

2 tons- Dump truck typically has a 5 to 6 yard capacity.

200

Undermount sink removal includes this. 

The sink and p-trap

200

Thermal Imaging- why is it not a customary item?

Thermal imaging detects temperature changes not moisture and many things can contribute to temperature changes. Best practices would still require moisture readings with a moisture meter. 

200

A large dehu can handle what PPD?

70-109


300

Adjuster needs updated how often?

every 5 days

300

Good moisture readings include these

- Drying goal- taken from an unaffected area within the loss site. 

- What material was the moisture reading taken from

- Type of meter used ( different types are for different materials) 

300

Sink detach includes this. 

Faucet- 

300

Why don't they need a supervisor?

All technicians on site should be certified and able to complete all tasks without direct supervision.

Rare occasions this can be confirmed but this is rare- we would want to try to include a small amount of additional tech labor, if it is reasonable. It shouldn't be a typical thing we are confirming on our comparatives.

300

Required PPD for Category 3, Class 1 

CF= 14,907.51

149.08

400

Submersible pumps can pump out how many gallons of water per hour 

between 3,000 and 4,800 gallons per hour 

Typically seen in crawlspaces or basements- not very common 

This equipment is charged per hour so it's important to do the math. The calculation is also shown in Xactimate

Calculate gallons: depth in inches * 0.6235 * SF of area

400

This equipment is based on CFM not PPD to determine what size is needed. 

Air Scrubbers

Desiccant Dehumidifier- this is because they work by a chemical reaction to draw the moisture from the air. 

Class 1- 1 ACH

Class 2- 2 ACH

Class 3 and 4 - 3 ACH

400

Wood floor drying mat system can handle how many SF per unit?

100-400 of floor surface per unit- this item is not per mat but per unit in Xact. (including blower, hoses, mats, etc.).

400

Why isn't O&P  standard for mitigation, content, specialty services, etc.

O&P is designed for use by general contractors when 3 or more trades are being performed. This is because there may be unforeseen costs the contractor may face. Mitigation services do not contain 3 or more trades and ALL associated costs are included in the Xactimate line items. 

400

cfm 1,045.96 would require how many air scrubbers?

1 Large unit- handles up to 1,399CFM 

2 Standard units- each handles up to 599CFM

500

This is where we can find the total amount of labor hours included in the line items on scope of work. 

Labor Summary- this is beneficial when the ctr is requesting additional labor. We can pull this up and explain to the ctr exactly how much labor is included. 

500

HEPA sandwich includes this- this is common on mold and abatements. 

HEPA Vac

Agitated Scrub

HEPA Vac 

500

90LF is what is covered by this drying equipment

Wall cavity injection dry- Blower, tubing, manifold, injectors, air mover (if used as part of the system), and all accessories for up to 90 lf of walls.

500

Ctr says they need a bigger dehu than ppd supports- "cause it helps dry quicker" 

Is this true or false

False- as too much dehumidification can cause damages to the materials. 

500

Required PPD for Category 1, Class 4

CF=12,698

317.45

M