Emergency Alarms
Intrusion Alarms
Power Alarms
Access System Alarms
Communication Alarms
100

Indicates a flame emergency at the customer site

What is a FIRE ALARM?

100

Generic descriptor for an alarm received, looking at the Location area will provide further information as to the details specific to the alarm itself

What is a GENERAL ALARM INPUT?

100

Indicates power has restored after a total power loss or displays after a panel download and after an enable-panel command

What is a PANEL UP?

100

Descriptor for an alarm received when an access door is accessed improperly without the use of an access card or fob

What is DOOR FORCED OPEN?

100

Indicates the panel is communicating on the secondary phone line

What is BACK UP Phone Line Active?

200
A function of the keypad when a code is entered signifying an ambush or distress situation and requires a police dispatch

What is a DURESS?

200

An alarm indicating the frequency of breaking glass

What is a GLASS BREAK ALARM?

200

Indicates power to the control panel has been down for at least one minute (5 minutes for ADV+ panels) and the panel is now operating on battery power

What is AC POWER DOWN?

200

Descriptor received indicating the number of events that an AAM can hold without overwriting itself has reached a critical mass (80%) and needs uploaded right away

What is an ACTIVITY BUFFER FULL?

200

Indicates the primary line communicating over IP (internet) may be down

What is IP CONN FAIL?

300

A distress situation initiated by pressing a hardwired or wireless emergency button device signifying that police need to be dispatched immediately

What is a HUB/HOLD UP BUTTON?

300
General descriptor for an alarm received covering the "edges" of a protected area

What is a PERIMETER ALARM?

300

Indicates the back-up battery is running low and has limited time remaining

What is LOW BATTERY?

300

Descriptor for an alarm received when an access door is held open too long

What is a DOOR PROPPED OPEN?

300

Indicates the primary phone line may be down as it has detected the loss of voltage for one minute on the telephone line and transmits this alarm on the secondary line/pathway if available

What is Phone Line 1 Down?

400

A distress situation initiated by pressing a hold-up button or other hardwired or wireless emergency detection device

What is a POLICE ALARM?

400

The system has detected an intrusion sound; look to the location column for a description of where the activation occurred within the facility

What is an AUDIO ACTIVATION?

400

Indicates a total loss of power (both primary and back-up); the panel is inoperative at this point and cannot send further alarms until power is restored

What is DOWN PANEL?

400

Descriptor received when the Access Module is not functioning properly and failing to communicate with the host panel

What is AAM DOWN?

400

The panel has not communicated with SonIP within the programmed "contact check" interval (typically 24 hours) so it generates this alarm code

What is a No Contact?

500

Indicates a fire alarm whereby the sprinkler system has activated

What is a WATER FLOW ALARM?

500

Indicates that the optioned delay time has expired after a delay point has been triggered

What is a DELAY ALARM?

500

Indicates AC power is present but the battery backup is inoperative (battery dead or a fuse is blown)

What is a BATTERY PROBLEM?

500
Descriptor signifying the AAM has lost power but should be functioning properly so long as the battery power remains

What is MODULE POWER-RELATED FAILIURE?

500

Communication between the receiver and the control panel has been interrupted

What is Line Interrupted?